      1. Our product

        make your life more

        comfortable
        Our Products
        name

        Temperature regulating dehumidifier

        model

        調(diào)溫除濕機(jī)

        Beautiful products, reliable performance, stable operation
        Performance < / th >Model < / th >
        TW-7STW-8.8STW-10STW-15STW-20S

        Machine

        Group

        Sex

        Yes

        Dehumidification capacitykg/h7.38.510.115.221
        Cooling capacityKW10.511.912.520.425.2
        Heating capacityKW4.54.56912
        Air volume㎡/h20002300260040005000
        External static pressurePa0~300~300~300~400~40
        Power supply3/NPE   AC   380V    50HZ 
        Input powerKw2.83.13.56.28.1
        CompressorTypeTotally enclosed rotary compressor
        Quantity11122
        RefrigerantUse of working fluidsR22
        Form of controlExternal balanced thermal expansion valve

        Room

        Inside

        Machine

        Evaporator form

        High efficiency copper tube with aluminum fin

        FanTypeHigh efficiency centrifugal fan 

        Filter

        Type

        Black double nylon filter

         

        Connecting pipe

        Connecting pipe mode

        Threaded connection

         

        Liquid pipe & phi; (mm)

        1×Φ10

        1×Φ12

        1×Φ122×Φ122×Φ12

        Trachea & phi; (mm)

        1×Φ16

        1×Φ19

        1×Φ192×Φ192×Φ19
        ShapeLength (mm)59876776711871187
        Width (mm)406463463500500
        Height (mm)16181720172017481748
        Weightkg607276150165

        Room

        Outside

        Machine

        Quantity

        Primary filter

        Condenser type

        High efficiency copper tube with aluminum fin

        Condensing fanType

        High efficiency axial flow fan

        Quantity11122
        ShapeLength (mm)8401426
        Width (mm)736814
        Height (mm)7801050
        Weightkg110110115200210

        1. There are two modes of dehumidification and air conditioning. Dehumidification mode is suitable for low ambient temperature, while air conditioning mode is suitable for high ambient temperature and cooling.
        2. In the dehumidification mode, the user can also adjust the temperature of the outlet air according to the needs to realize the functions of cooling dehumidification, heating dehumidification and constant temperature dehumidification.
        3. The refrigeration system has the advantages of reasonable structure, good air tightness, high reliability and easy installation and use.
        4. Famous brand, high efficiency, low energy consumption.
        5. Dehumidifier is automatic control type, including mechanical control type and microcomputer control type. Microcomputer control type, through key input, automatic display of relative humidity, automatic startup or shutdown, automatic detection and automatic control according to the humidity set by the user. ·
        6. Dehumidifiers are equipped with a variety of safety protection devices to ensure that the compressor is not damaged. &The dehumidifier is convenient for maintenance. It can work normally in the range of 40-95% relative humidity and 18-38 ℃ ambient temperature.
        1、 Application of temperature regulating dehumidifier&Temperature regulating dehumidifier can heat, cool and dehumidify the use environment to meet the indoor temperature and humidity requirements. The temperature regulating dehumidifier uses the evaporator to cool and dehumidify the air, and recovers the condensation heat of the system to make up for the heat lost in the air due to cooling and dehumidification. It is an efficient and energy-saving dehumidification method. It has been widely used in national defense engineering, civil air defense engineering, tobacco, petrochemical, electronics, aerospace, purification engineering, laboratory, telecommunications equipment room, archives, food room, medicine, special glass and other places with high requirements on temperature and humidity.
        2、 Advantages of outdoor unit features: < br / >&There are two modes of dehumidification and air conditioning. Dehumidification mode is suitable for low ambient temperature, while air conditioning mode is suitable for high ambient temperature and cooling.
        &2. In the dehumidification mode, the user can adjust the temperature of the outlet air according to the needs to realize the functions of cooling and dehumidification, heating dehumidification and constant temperature dehumidification.
        &3. The refrigeration system has reasonable structure, good air tightness, high reliability and easy installation.
        &4. Famous brand compressor and high efficiency heat exchanger are adopted. The whole machine has small volume, light weight, low energy consumption and high efficiency. &The dehumidifier is of automatic control type, including mechanical control type and microcomputer control type. Microcomputer control type, through key input, automatic display of relative humidity, automatic startup or shutdown, automatic detection and automatic control according to the humidity set by the user. &Middot; dehumidifiers are equipped with a variety of safety protection devices to ensure that the compressor is not damaged. &The dehumidifier is convenient for maintenance. It can work normally in the range of 40-95% relative humidity and 18-38 ℃ ambient temperature.
        3、 Working principle of temperature regulating dehumidifier: < br / >&When using the ambient air to pass through the evaporator surface, because the evaporator temperature is lower than the dew point temperature of the air, the water vapor in the air accumulates in the water pan and is discharged by the water pipe, so the moisture content of the air decreases. According to the user’s requirements for the ambient temperature and humidity, the indoor temperature rise, refrigeration and dehumidification can be carried out.
        4、 Temperature regulating dehumidifier is generally purchased1. Measure the volume and area * height of the space to be used (converted to the usable area by 2.6m after measurement).
        2. Considering the humidity range that you need, the humidity range of general space is about 60%, and the humidity range of valuables is about 50%.
        3. The general space humidity range is configured according to 1-1.2 times of the use area per liter of dehumidification capacity; < br / > 04. Of course, we can enlarge the proportion of the used area, but the larger the area is, the longer the dehumidification time is required.
        5. When used in special environment, please consult the sales consultant for the specific use plan.